Correct source for temperature sensor for devices with RAID controller

New:

  • New article


Last adaption: 07.2020


Affected devices

Appliances with RAID controller

  • RC 400 G3
  • RC 1000 G3

Problem description

For devices with a RAID controller it is important that the temperature source of the fans in the bios is correctly set to System Temperature.

If the value CPU Temperature(DTS) is entered here, the controller may become too hot.
The device signals this with a continuous alarm tone.


Entering the Bios

The change into the Bios is done by pressing the key Entf during the boot process

Menu Advanced
► Hardware MonitorPic.1
► Smart Fan FunctionPic.2

Fan 1 / Temperature Source
System TemperaturPic.3

Fan 2 / Temperature Source
System TemperaturPic.4